| Availability: | |
|---|---|
| Quantity: | |
The FKH-100IICGW, a high-temperature air-source heat pump from Leomon Technology, delivers a powerful 100 kW heating capacity, providing reliable hot water up to 90℃. It is engineered for demanding applications in hotels, hospitals, and various industrial settings. Equipped with an advanced cascade two-stage compression system and a specialized high-temperature refrigerant, this unit boasts exceptional energy efficiency and stable performance even in extreme cold.
Utilizing intelligent microcomputer controls and remote monitoring capabilities, the system maintains optimal operation while simplifying complex management. The FKH-100IICGW ensures highly efficient and dependable high-temperature hot water solutions for your critical needs, guaranteeing superior results and peace of mind.
Seamless Multi-Energy System Integration
The FKH-100IICGW is designed for effortless integration with other renewable energy sources, such as solar energy and geothermal systems. This capability allows for the creation of a comprehensive, highly stable, and complementary heating framework, maximizing energy efficiency and environmental benefits while ensuring a diversified and resilient heat supply.
Minimized Comprehensive Attenuation for Consistent Performance
The high-temperature heat pump system is engineered to exhibit a comprehensive ability attenuation that does not exceed 10% even in demanding low-temperature environments. This means the system maintains its high energy efficiency and requires less electricity consumption to deliver the same heating capacity, ensuring consistent and reliable performance throughout its operational range.
Unwavering Stable Operation in Extreme Cold
Thanks to its innovative dual-level stacking technology and two-stage compression system, the FKH-100IICGW guarantees stable operating pressure and optimal heating performance even when ambient temperatures plummet to a challenging -35℃. This advanced capability effectively prevents common shutdowns experienced by single-air source heat pump systems in severely cold climates, ensuring continuous hot water supply.
Intelligent & Customizable Control with Remote Management
Equipped with an advanced microcomputer control board, the FKH-100IICGW offers precise operational control, comprehensive protection, and allows users to flexibly personalize their heating experience by setting different temperature levels for various time intervals. Seamlessly integrated with 5G cloud technology, it enables real-time remote monitoring and control via a mobile app (on/off, settings, fault diagnosis, alarms), significantly boosting management efficiency and responsiveness.
Ultra-Quiet Operation with Advanced Noise Reduction
The FKH-100IICGW ensures exceptionally quiet performance through advanced biomimetic fan blades that minimize wind noise, alongside specially engineered silent compressors, efficient axial fans, and sound-absorbing technology. This comprehensive design results in remarkably low operational noise, creating a comfortable and less disruptive environment, ideal for noise-sensitive applications.
Comprehensive Multiple Safety Protections
Safety is paramount, and this heat pump integrates 11 extensive equipment self-check protections. These include crucial safeguards such as compressor exhaust temperature protection, high/low pressure protection, antifreeze protection, overload protection, and power outage memory recovery, ensuring supremely safe, reliable, and continuous operation.

| Type | FKH-100II/CGW |
| Top out wind | |
| Power specifications | 380V 3N~50Hz |
| Heating capacity under A1 operating condition(20) | 100kW |
| Heating consumption power under A1 working condition | 47.6kW |
| Heating capacity under A2 working condition(7) | 95kW |
| Heating consumption power under A2 working condition | 50kW |
| Heating capacity under A3 working condition(-12) | 90kW |
| Heating consumption power under A3 working condition | 56.5kW |
| Heating capacity under A4working condition(-20) | 80kW |
| Heating consumption power under A4 working condition | 55.2kW |
| Maximum operating current | 160A |
| Discharge | 17.2m³/h |
| Noise | ≤68dB(A) |
| Water side pressure loss | ≤85kPa |
| Unit size (length x width x height mm) | 2260×1230×2170 |
| CONNECT SIZE | DN65(flange) |
| Unit weight (kg) | 1110 |
1.Hotel:
In the hot water system, it can provide stable high temperature hot water, ensuring that guests can enjoy comfortable hot water service at any time. It can also be used for dry cleaning and sterilization in hotel laundry rooms, as well as steam drying, which is more efficient and saves energy consumption compared to traditional electric drying.
2.Hospitals:
Meets the critical and continuous demands for high-temperature hot water supply throughout medical facilities. It is also effectively utilized for drying and disinfecting clothing and linens in hospital laundries, ensuring sterile environments.
3.School:
Provide centralized heating and domestic hot water for the school, using air source heat pumps with underfloor heating, and adopting low flow rate and large temperature difference. The monthly heating cost can save more than 50% compared to electric heating, and more than 30% compared to gas wall mounted boiler heating.
4.Swimming Pool:
Maintains constant pool water temperatures with exceptional energy efficiency, potentially saving up to 80% in operating costs when compared to traditional boiler methods. Additionally, the system often includes integrated fresh air and dehumidification functions, contributing to improved indoor air quality and comfort.
>> Product Operate Guide
Upon taking delivery of the goods, the purchaser will furnish an instructional video.
Q1.What should I do if the heat pump produces loud noise during operation?
A: Regularly check the equipment status and replace aging components such as compressors and fans in a timely manner. Ensure stable installation of equipment and reduce vibration and noise generation.
Q2.What should be done if the heating efficiency decreases in a low-temperature environment?
A: Choose a two-stage compression or cascade heat pump (such as the COLDNOT model) to ensure stable operation at -35 ° C; Install auxiliary electric heating, but pay attention to the increase in energy consumption.
Q3.What if you don't know how to use a heat pump?
A: Provide detailed user manuals and maintenance guidelines to guide users in the correct use and maintenance of the heat pump; Regularly conduct user training and technical support activities to enhance users' usage skills and maintenance awareness.
Q4. What is the minimum order quantity (MOQ) ?
A: 1 units.
Q5. Do you provide OEM or private labeling?
A: Yes. We offer OEM/ODM services, including: Logo printing and Custom packaging.
Q6. Do you offer technical training and support?
A: Yes. We provide: Online and on-site training for sales and technicians, Detailed installation manuals and wiring diagrams, Troubleshooting guides, Remote video support during first installations, etc.