+86-17355573160     wendy@lnashp.com
air source heat pump dryer for sale
Home / Blogs / Industry Knowledge / What Is The Maximum Temperature for Air Source Heat Pump?

What Is The Maximum Temperature for Air Source Heat Pump?

Views: 0     Author: Site Editor     Publish Time: 2025-12-22      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
sharethis sharing button

For decades, a persistent myth has limited the adoption of sustainable heating technology. Many facility managers and homeowners believe heat pumps are only suitable for modern, highly insulated spaces with low-temperature underfloor heating. They assume that if you need water hotter than 55°C or live in a freezing climate, you must stick with fossil fuels. This outdated view ignores significant technological advancements.


The reality is far more capable. Today, a specialized class of High-Temperature Air Source Heat Pump systems can deliver water temperatures ranging from 60°C up to 120°C. These units enable decarbonization in challenging environments, from uninsulated historic renovations to energy-intensive industrial manufacturing lines.


This guide clarifies the technical boundaries of "Maximum Temperature." We will examine two distinct limits: the maximum output temperature (flow temp) for radiators or industrial processes, and the operational limits regarding extreme ambient cold. You will learn how modern engineering overcomes these barriers to provide reliable, high-grade heat without gas or coal.


Key Takeaways


  • Standard vs. High-Temp: Standard units top out at 55°C; High-Temperature Air Source Heat Pumps utilize cascade cycles to reach 80°C–90°C for residential retrofits and up to 120°C for industrial drying.

  • Cold Climate Resilience: Specialized EVI (Enhanced Vapor Injection) technology maintains heating capacity down to -35°C, suitable for regions like Heilongjiang.

  • The Efficiency Trade-off: Higher output temperatures reduce Coefficient of Performance (COP). Financial viability depends on the "Temperature Lift" required vs. the cost of fossil fuel alternatives.

  • Primary Use Cases: Older building retrofits (keeping existing radiators), textile printing/dyeing (60–80°C), and electroplating insulation (85°C).


Defining the Limits: Output Temperature vs. Ambient Range

To select the right equipment, you must distinguish between two types of "temperature limits." Buyers often confuse how hot the water gets with how cold the outside air can be. While related, they require different engineering solutions.


Maximum Output Temperature (Flow Temp)

Output temperature determines what kind of heating infrastructure you can support. We generally categorize systems into two classes based on their thermal capability.

  • Residential Retrofit Class (65°C to 80°C): These units replace gas or oil boilers in older properties. Historic buildings often have cast-iron radiators sized for high-temperature water. A standard heat pump outputting 50°C would leave these rooms cold. High-temperature models output 75°C to 80°C, allowing you to keep existing pipework and radiators intact.

  • Industrial/Commercial Class (90°C to 120°C): This is the frontier of heat pump technology. Known as 120℃ Ultra-High Temp High-Temperature units, they are designed for process heat. They replace steam boilers in manufacturing, supporting applications like sludge drying, sterilization, and food processing.


Ambient Operating Limits

This limit defines the environment where the machine survives and functions. It answers the question: "Will it work when winter hits its peak?"

  • The Cold Threshold: Standard residential units often lose significant capacity below -5°C and may cut out entirely at -15°C. In contrast, a -35℃ Cold-Resistant High-Temperature Air Source Heat Pump is engineered for extreme climates. These systems utilize specialized compressors and injection technologies to extract heat even when the air feels frozen solid.

  • Heat Rejection (Cooling Mode): Industrial units often face the opposite problem. If you use the heat pump for cooling or heat recovery in a hot factory, the "design temperature" for the condenser becomes critical. Many units cap out at 43°C ambient. If your facility gets hotter than this, you need specific condensers sized for high-ambient heat rejection.


The Technology Behind High-Temperature Performance

Skepticism is natural. How can a machine take freezing air and turn it into steam? It relies on advanced thermodynamic cycles that differ significantly from the simple air conditioner found in most homes.


Cascade Refrigeration Systems

Standard heat pumps use a single refrigeration loop. To reach very high temperatures, a single compressor would need to create dangerous internal pressures. The solution is a "Cascade" system.

A cascade system uses two separate refrigeration cycles working together:

  1. Low Stage: The first cycle (often using R410A or R32) extracts heat from the outside air and lifts it to an intermediate temperature (e.g., 40°C).

  2. High Stage: The second cycle (often using R134a or R1234ze) takes that intermediate heat and compresses it further.

Since the second compressor starts with "warm" heat, it can easily boost the output to much higher levels. This dual-stage approach is how we achieve a stable 90℃ Ultra-High Temp High-Temperature supply without overworking the mechanical components.


Enhanced Vapor Injection (EVI)

For operation in extreme cold, manufacturers employ Enhanced Vapor Injection. Standard compressors overheat and lose pressure when the outside air is too cold. EVI acts like a turbocharger for the compressor.

It injects a mid-pressure refrigerant vapor directly into the compressor head. This cools the compressor internally and increases the mass flow of the refrigerant. The result is a system that maintains high heating capacity even when outdoor temperatures plummet. This technology is standard for Heilongjiang cold region office building heating projects, where reliability at -30°C is a safety requirement, not just a comfort preference.


Next-Gen Refrigerants

The chemical medium inside the heat pump dictates its thermal limits. Two refrigerants are leading the high-temperature shift:

  • CO2 (R744): Carbon dioxide is unique. It operates at very high pressures and is excellent for heating water from cold to hot in a single pass. It can reach 90°C efficiently, making it ideal for sanitary hot water systems.

  • R290 (Propane): This natural refrigerant has excellent thermal conductivity. It allows single-stage compressors to reach flow temperatures of 70°C+, combining high performance with a low Global Warming Potential (GWP).


Commercial & Industrial Use Cases (60°C to 120°C)

High-temperature heat pumps are not just for heating radiators. They solve high-value business problems by displacing expensive fossil fuels in industrial processes. We can categorize these by the temperature precision they require.


Textile Printing and Dyeing (60–80°C)

The textile industry consumes massive amounts of water and heat. Dyeing vats must be kept at precise temperatures to ensure color fastness. Traditionally, factories use coal or gas steam boilers, which are inefficient for mid-range heating.


Textile printing and dyeing factory 60-80℃ hot water supply system allows the facility to switch to electrification. The heat pump provides the exact temperature required for rinsing and dyeing without the energy waste associated with stepping down high-pressure steam. This switch can reduce operating costs significantly while decarbonizing the supply chain.


Electroplating Solution Insulation (85°C)

Electroplating lines require baths to be maintained at constant high temperatures to ensure proper metal adhesion. Electric resistance heaters are common here, but they operate at a COP (Coefficient of Performance) of 1.0—meaning one unit of electricity creates one unit of heat.


By installing a specialized heat pump for Electroplating solution 85℃ insulation, facilities can achieve a COP of 2.0 or higher. This cuts the electricity bill for heating these tanks in half. The heat pump maintains the strict 85°C requirement, ensuring quality control is never compromised.


Industrial Drying & Steam Generation (90°C–120°C)

Drying is one of the most energy-intensive processes in manufacturing, whether for food, sludge, or lumber. These processes often rely on hot air or steam at temperatures above the boiling point.

Using 120℃ Ultra-High Temp High-Temperature industrial units, manufacturers can recover waste heat from other parts of the factory and upgrade it to drying temperatures. This circular energy approach transforms waste heat into a valuable asset, replacing direct fossil fuel combustion.


Evaluating Feasibility: Efficiency vs. Temperature Lift

High-temperature heat pumps are powerful, but they are subject to the laws of physics. Understanding the trade-offs is essential for a viable project.

The "Lift" Factor

Efficiency is driven by "Temperature Lift"—the difference between the source temperature (outside air) and the target temperature (output water). The larger the lift, the harder the compressor works, and the lower the efficiency.

Ambient Temp (Source)Output Water Temp (Target)Lift (Delta T)Estimated COPEfficiency Note
7°C35°C28°C~4.5Excellent (Underfloor)
7°C80°C73°C~2.2Moderate (High Temp)
-10°C55°C65°C~2.0Standard Winter
-10°C85°C95°C~1.6High Lift (Industrial)

Heating water to 80°C when it is -10°C outside requires a massive lift. While technically possible, the COP may drop to around 1.8. However, compared to a gas boiler with an efficiency of 0.9, the heat pump is still twice as efficient.


TCO (Total Cost of Ownership) Calculation

When calculating costs, consider both Capital Expenditure (CapEx) and Operational Expenditure (OpEx).

  • CapEx: High-temperature units utilize complex components like dual compressors and EVI circuits. Expect them to cost 20–40% more upfront than standard low-temperature units.

  • OpEx: Even at lower efficiencies (COP 2.0), industrial heat pumps frequently beat oil and LPG costs. Against cheap natural gas, the calculation requires precision. You must weigh the price per kWh of electricity against the price per therm of gas.


Retrofit vs. Replacement Logic

For older office buildings, the decision often comes down to disruption. Is it cheaper to install high-temp pumps and preserve the old radiators? Or is it better to gut the building, install fan coils, and use a standard heat pump? In occupied buildings or historic sites, the high-temperature heat pump is often the winner because it avoids the massive labor cost and downtime of replacing internal distribution systems.


Implementation Risks & Selection Criteria

Selecting the wrong unit for a high-temperature application can lead to system failure or skyrocketing energy bills. Follow these criteria during the shortlisting phase.

Sizing for the "Worst Case"

Never size a system based on average conditions. You must ensure the unit is rated for the Maximum Capacity at Minimum Ambient Temp. For example, you need a unit that can maintain 100% of the heating load at -20°C without relying on backup electric resistance heaters. Always check the manufacturer's capacity tables at your region's design temperature, not just the nominal rating at +7°C.


Defrost Cycle Management

In humid, cold climates (around 0°C to +5°C with high humidity), heat pumps are prone to icing. High-temperature units work harder, making them more susceptible to frost build-up on the outdoor coil. Evaluate the unit's defrost logic. Intelligent systems use sensors to defrost only when necessary, minimizing downtime. In critical industrial processes, you may need a buffer tank to provide heat while the unit is in defrost mode.


Power Supply Infrastructure

Industrial high-temperature units, especially Cascade systems, draw significant power. A standard residential supply may not be sufficient. You must assess the existing 3-phase capacity of the facility. If the electrical infrastructure needs a major upgrade to support the heat pumps, this cost must be factored into the ROI calculation early in the project.


Conclusion

High-temperature air source heat pumps have successfully broken the 55°C barrier. They now reliably serve 80°C residential retrofits and meet 120°C industrial demands. This technology bridges the gap for buildings and factories that cannot easily improve insulation or swap out distribution systems.


While they solve the problem of high-grade heat demand without fossil fuels, they require precise engineering. The trade-off between higher temperatures and efficiency is a physical reality that must be managed.


For standard homes, seeking proper insulation is still the first step. However, for industrial applications like textile printing or electroplating, a detailed thermal audit is the path forward. By calculating the specific ROI based on your current energy prices, you can determine if high-temperature heat pumps are the key to your decarbonization strategy.


FAQ

Q: Can an air source heat pump really heat water to 90°C?

A: Yes, but this requires specialized commercial systems, typically using "Cascade" refrigeration cycles or CO2 (R744) refrigerant. Standard residential units typically max out at 55°C–60°C. High-temperature units are specifically engineered with dual compressors to achieve these levels efficiently.


Q: Does a heat pump work efficiently at -35°C?

A: Standard pumps often stop or rely entirely on electric backup at these temperatures. However, -35℃ Cold-Resistant High-Temperature units equipped with EVI technology can continue to extract heat. While they work, the efficiency (COP) will be lower, likely closer to 1.5–1.8, compared to their performance in milder weather.


Q: Is it better to replace radiators or buy a high-temperature heat pump?

A: It depends on labor costs and disruption tolerance. If changing radiators damages the building fabric (e.g., in historic sites) or disrupts operations, a high-temperature heat pump is the better TCO choice. It allows you to keep the existing infrastructure, even though the running costs might be slightly higher than a low-temperature system.


Q: What is the lifespan of a high-temperature heat pump running at 80°C?

A: Running at maximum temperature constantly adds stress to the compressor. Industrial units are designed for this load, but residential units should utilize "Weather Compensation." This feature adjusts the water temperature based on the weather, ensuring the unit only hits maximum temperatures on the coldest days, typically preserving compressor life for 15–20 years.


Leomon Technology is a leading manufacturer and innovator in the field of high-performance heat pump solutions, specializing in air source, EVI, R290, CO₂, and high-temperature heat pumps for residential, commercial, and industrial applications.

Quick Links

Product Category

Contact Us
Copyright © 2025 Maanshan Leomon Energy-Saving Technology Co., Ltd. All Rights Reserved.| Sitemap | Privacy Policy