| Availability: | |
|---|---|
| Quantity: | |
The FKH-110II GW 75 Degree Inverter Air Source Heat Pump – a high-performance solution for demanding commercial and industrial heating needs. These units redefine large-scale heating with superior performance and exceptional energy efficiency.
As an inverter-driven system, the FKH-110II GW offers superior energy efficiency and precise temperature control, adapting output to exact requirements. It operates reliably in diverse climates, including challenging low ambient temperatures. Built with industrial-grade components, it ensures robust performance and longevity. Ideal for hot water supply, process heating, and space heating in hotels, factories, and commercial buildings, the FKH-110II GW is a smart, sustainable investment.
High efficiency, low energy efficiency:
In extremely cold environments, compared to traditional low-temperature air source heat pumps, the overall capacity attenuation is smaller and the energy efficiency is higher. The comprehensive energy attenuation rate shall not exceed 10%, and the lower the ambient temperature, the higher the heating water temperature, meeting the requirements of end of pipe thermal matching.
Wide Operating Temperature Range:
Our products are built to perform reliably across a broad spectrum of ambient temperatures, including extreme cold conditions (down to -20°C). This ensures consistent heating performance regardless of the climate, providing peace of mind and stable operation throughout the year, even in challenging environments.
Stable Operation in Extreme Cold:
The dual-stage stacking technology with dual compressors ensures stable operation and optimal conditions even at -20°C, preventing shutdowns common in single air source units due to high compression ratios in severe cold.
Robust Industrial Design:
Featuring a durable and substantial construction, including industrial-grade power specifications (380V 3N~50Hz) and robust flange connections (DN65), these units are built to withstand the rigors of continuous industrial and large commercial operation. Their design ensures reliability and longevity, minimizing downtime and maximizing productivity.
Integrated Intelligent Control & Remote Monitoring:
Features an advanced microcomputer control board for precise operational control and comprehensive protection. Seamlessly integrated with 5G cloud technology, it enables real-time remote monitoring, control via mobile app (on/off, settings, fault diagnosis, alarms), significantly boosting management efficiency and responsiveness. Users can also customize temperature settings for different time intervals.
Type | FKH-110II/GW |
| Top out wind | |
Power specification | 380V 3N~50Hz |
Heating capacity under A1 operating condition (20) | 110kW |
Heating consumption power under A1 working condition | 44.5kW |
Heating capacity under A2 working condition (7) | 105kW |
| Heating consumption power under A2 working condition | 48kW |
Heating capacity under A3 working condition (-12) | 90kW |
Heating consumption power under A3 working condition | 52kW |
Heating capacity under A4 working condition (-20) | 80kW |
Heating consumption power under A4 working condition | 49.6kW |
Maximum operating current | 160A |
Discharge | 18.9m³/h |
Noise | ≤68dB(A) |
Water side pressure loss | ≤85kPa |
Unit size (length x width x height mm) | 2260×1230×2170 |
CONNECT SIZE | DN65(flange) |
Unit weight (kg) | 1100 |
Agricultural greenhouse heating:
In agricultural greenhouses, heating equipment is required to maintain a suitable temperature to promote plant growth. High temperature heat pumps can serve as an environmentally friendly and efficient heating method, providing a stable heat source for greenhouses.
Medium Commercial and Public Buildings:
This unit is well-suited for medium-sized office buildings, community shopping centers, or multi-story residential blocks with a total floor area ranging from approximately 5,000 to 10,000 square meters. It effectively provides winter heating and a stable supply of domestic hot water, ensuring a comfortable indoor environment.
Regional or Decentralized Hotels/Guesthouses:
Ideal for mid-sized business hotels, boutique hotels, or single buildings within a hotel chain featuring around 80 to 150 guest rooms. The 110kW unit can meet the heating demands for guest rooms, dining areas, and public spaces, while also supplying ample hot water for showers. The 110kW unit is perfectly suited for mid-sized hospitality venues.
Sections of Large Schools (Teaching/Dormitory Buildings) or Hospitals:
This unit can provide centralized heating and hot water for specific teaching buildings, libraries, or individual dormitory blocks within a larger school campus. In a hospital setting, it can serve an outpatient building, a particular ward building, or administrative offices. The 110kW model focuses on servicing distinct functional areas or single buildings.
Medium Industrial Ancillary Workshops or Non-High Heat Consumption Facilities:
Suitable for production workshops in industries like textiles, garment manufacturing, or small-scale electronics assembly, where the process temperature requirements are not extremely high, but space heating and domestic hot water for employees are essential. It can also be used for administrative buildings, cafeterias, or staff rest areas within larger industrial complexes. This unit is distinct from the 140kW unit as it caters to auxiliary or less heat-intensive production environments, while the 140kW unit directly addresses core, high-heat-load production processes.

>> Product Operate Guide
Upon taking delivery of the goods, the purchaser will furnish an instructional video.
Q1.How to choose the installation location?
A: Ensure that the heat pump is installed in a well ventilated area and away from direct sunlight; The pipeline connection must be tight and leak free; Reasonably set parameters based on environmental temperature and usage requirements during debugging.
Q2.What should be done if the heat pump fails to start, runs unstably, or suddenly shuts down?
A: It is recommended to conduct periodic safety inspections on the electrical circuits and key components of the equipment, with a frequency of no less than once every quarter, focusing on checking the tightness of the wiring terminals, the integrity of the insulation layer, and signs of cable aging; If problems such as poor contact, insulation damage, or abnormal heating are found, the machine should be immediately shut down and a qualified electrician team should be commissioned to conduct systematic maintenance and preventive maintenance, and the electrical safety records should be updated simultaneously.
Q3.How to deal with refrigerant leakage?
A: Regularly inspect refrigerant pipelines and connecting components, promptly identify and repair leakage points; Ensure that the refrigerant charge meets the equipment requirements.
Q4. What is the minimum order quantity (MOQ) ?
A: 1 units.
Q5. Do you provide OEM or private labeling?
A: Yes. We offer OEM/ODM services, including: Logo printing and Custom packaging.
Q6. Do you offer technical training and support?
A: Yes. We provide: Online and on-site training for sales and technicians, Detailed installation manuals and wiring diagrams, Troubleshooting guides, Remote video support during first installations, etc.