| Availability: | |
|---|---|
| Quantity: | |
The FKH-110II/GW is meticulously engineered to provide a powerful yet exceptionally energy-efficient heating solution. As an energy-saving device that leverages high-level energy to transfer low-level heat sources to high-level ones based on the inverse Carnot cycle, this system possesses the capability for heating, cooling, and hot water supply. With a robust design and a formidable heating capacity of up to 110kW, this unit is perfectly suited for a diverse array of medium-to-large scale applications where reliable warmth, efficient climate control, and operational economy are paramount. Utilizing an innovative "Top Out Wind" discharge design, the FKH-110II/GW optimizes air circulation and heat exchange, ensuring consistent and effective performance. This system harnesses ambient energy, significantly reducing reliance on conventional heating methods and contributing to substantial energy savings and a lower carbon footprint.
Exceptional 110kW Heating Power:
At its core, the FKH-110II/GW boasts a substantial heating capacity of 110kW under optimal A1 operating conditions, ensuring ample and rapid heat delivery to meet even demanding requirements for space heating or hot water generation. This significant output guarantees comfort and efficiency across large areas.
Robust Performance in Diverse Climates:
Engineered for reliability, the FKH-110II/GW operates effectively across a wide spectrum of ambient temperatures. From mild 20℃ down to a challenging -20℃, its performance remains stable and powerful, making it an ideal heating solution for various geographical regions and seasons, ensuring consistent warmth regardless of external conditions.
Space-Efficient "Top Out Wind" Design:
The compact unit dimensions of 2260mm (length) x 1230mm (width) x 2170mm (height), combined with its innovative "Top Out Wind" air discharge, optimize installation footprint. This design allows for more flexible placement, especially in areas where side clearance is limited, maximizing space utility.
Efficient Water Side Hydraulic Performance:
Engineered for optimal flow, the system exhibits a low water side pressure loss of ≤85KPa. This efficiency in water circulation minimizes pump energy consumption within the overall system, further contributing to the FKH-110II/GW's exceptional energy-saving profile.
Industrial-Grade Durability and Stability:
With a maximum operating current of 160A and a substantial unit weight of 1100 kg, the FKH-110II/GW is built to last. Its heavy-duty construction and robust internal components ensure long-term reliability and stable performance even under continuous, demanding industrial and commercial operation.
Optimized for Quieter Operation:
Despite its considerable power, the FKH-110II/GW maintains a remarkably low noise level of ≤68dB(A). This makes it suitable for installation in environments where noise control is a consideration, minimizing disruption to surrounding areas or operations.
Type | FKH-110II/GW |
Top out wind | |
Power specifications | 380V3N~50Hz |
Heating capacity under A1 | 110kW |
Heating consumption power under | 44.5kW |
Heating capacity under A2 | 105kW |
Heating consumption power under | 48kW |
Heating capacity under A3 | 90kW |
Heating consumption power | 52kW |
Heating capacity under A4working | 80kW |
Heating consumption power | 49.6kW |
Maximum operating current | 160A |
Discharge | 18.9m³/h |
Noise | ≤68dB(A) |
Water side pressure loss | ≤85kPa |
Unit size (ength x width x height mm) | 2260×1230×2170 |
CONNECT SIZE | DN65(flange) |
Unit weight (kg) | 1100 |
Commercial and Institutional Building Heating:
The FKH-110II/GW is an ideal choice for providing efficient and comprehensive central heating to large commercial complexes, office buildings, shopping centers, and public institutions such as schools and libraries, ensuring comfortable indoor environments year-round.
Sports and Leisure Facilities:
Capable of efficiently heating large volumes of water, the FKH-110II/GW is excellent for swimming pools, sports centers, fitness clubs, and recreational facilities, ensuring optimal water temperatures for various activities.
Agricultural and Horticultural Environments:
Supports modern agricultural and horticultural operations by maintaining precise temperatures in greenhouses, heating livestock facilities, or providing hot water for processing and sanitation, promoting optimal growth conditions and operational hygiene.

Distributed Heating Networks:
Can be integrated into localized or smaller-scale district heating systems, providing a centralized and energy-efficient heat source to supply hot water and heating to multiple residential or commercial properties within a defined area.
Hotels, Resorts, and Hospitality:
Perfectly suited for the demands of the hospitality sector, this heat pump reliably supplies large volumes of hot water for guest rooms, kitchens, laundries, and communal areas in hotels, resorts, and apartment buildings, enhancing guest comfort and operational efficiency.
1.How to choose the installation location?
Ensure that the heat pump is installed in a well ventilated area and away from direct sunlight; The pipeline connection must be tight and leak free; Reasonably set parameters based on environmental temperature and usage requirements during debugging.
2.What should be done if the heat pump fails to start, runs unstably, or suddenly shuts down?
It is recommended to conduct periodic safety inspections on the electrical circuits and key components of the equipment, with a frequency of no less than once every quarter, focusing on checking the tightness of the wiring terminals, the integrity of the insulation layer, and signs of cable aging; If problems such as poor contact, insulation damage, or abnormal heating are found, the machine should be immediately shut down and a qualified electrician team should be commissioned to conduct systematic maintenance and preventive maintenance, and the electrical safety records should be updated simultaneously.
3.How to deal with refrigerant leakage?
Regularly inspect refrigerant pipelines and connecting components, promptly identify and repair leakage points; Ensure that the refrigerant charge meets the equipment requirements.
4. What is the minimum order quantity (MOQ) ?
A: 1 units.
5. Do you provide OEM or private labeling?
A: Yes. We offer OEM/ODM services, including: Logo printing and Custom packaging.
6. Do you offer technical training and support?
A: Yes. We provide: Online and on-site training for sales and technicians, Detailed installation manuals and wiring diagrams, Troubleshooting guides, Remote video support during first installations, etc.