Leomon
| Availability: | |
|---|---|
| Quantity: | |
Utilizing two-stage cascade compression and multi-stage refrigerant heat exchange, this system reduces the compression ratio during operation, significantly enhancing both efficiency and performance in low-temperature environments. It achieves an innovative output water temperature of 95°C even when the ambient temperature is as low as -35°C, serving as an effective replacement for heating boilers in extremely cold regions.
Features
1. Capable of delivering an output water temperature of 85–95°C in ambient temperatures as low as -35°C.
2. Employs industry-leading ultra-low-temperature DC inverters and enhanced vapor injection (EVI) technology across both compression stages.
3. Features built-in Wi-Fi connectivity, allowing you to monitor the heat pump’s operating status at a glance—from anywhere in the world.
Advantages
1. Exceptional Performance Across Various Conditions
The heat pump system provides efficient home heating, cooling, and domestic hot water, even in extreme climates. It is well-suited for use throughout most of Europe.
2. High-Quality Compressors
Equipped with Panasonic compressors to ensure reliable operation and create an ideal, comfortable home environment.
3. EVI (Enhanced Vapor Injection) Technology
Thanks to EVI technology, the system maintains outstanding heating performance in low-temperature environments. It can deliver 95°C hot water even when the outdoor temperature drops to -15°C, and it remains stable in extreme cold—down to -30°C.
4. Comprehensive Anti-Freeze Protection
The system utilizes multiple anti-freeze measures, including water pump circulation, system-wide circulation, and chassis heating. It automatically monitors the temperatures of the main unit and piping; if the ambient temperature falls below 2°C and the water temperature drops below 7°C, the heat pump automatically initiates heating to 15°C, effectively preventing the system from freezing.
5. Intelligent Defrosting
Using multiple sensors to monitor operating temperatures in real-time, the system performs intelligent defrosting based on actual demand rather than a fixed schedule. This approach avoids unnecessary operation, making it more efficient and energy-saving.
Type | FKH-10I/CGW | FKH-18II/CGW | FKH-35II/CGW | FKH-70II/CGW | FKH-100II/CGW | FKH-130II/CGW |
Side air outlet | Top out wind | Top out wind | Top out wind | Top out wind | Top out wind | |
Power specifications | 220V~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz |
Heating capacity under A1 | 10kW | 18kW | 35kW | 70kW | 100kW | 130kW |
Heating consumption power under A1 | 4.8kW | 8.2kW | 16.8kW | 33.6kW | 47.6kW | 61.5kW |
Heating capacity under A2 working | 9.5kW | 17kW | 34kW | 68kW | 95kW | 125kW |
Heating consumption power under A2 | 5kW | 8.9kW | 17.9kW | 35.8kW | 50kW | 65.8kW |
Heating capacity under A3 working | 9.5kW | 17kW | 32kW | 64kW | 90kW | 110kW |
Heating consumption power | 6.2kW | 10.6kW | 20.6kW | 41.2kW | 56.5kW | 68.5kW |
Heating capacity under A4working | 8kW | 16kW | 30kW | 60kW | 80kW | 100kW |
Heating consumption power | 5.6kW | 11.1kW | 20.1kW | 40.2kW | 55.2kW | 68.9kW |
Maximum operating current | 40A | 35A | 70A | 120A | 160A | 200A |
discharge | 1.7m³/h | 3.1m³/h | 6m³/h | 12m³/h | 17.2m³/h | 24.1m³/h |
noise | ≤56dB(A) | ≤58dB(A) | ≤60dB(A) | ≤65dB(A) | ≤68dB(A) | ≤72dB(A) |
Water side pressure loss | ≤72kPa | ≤75kPa | ≤75kPa | ≤85kPa | ≤85kPa | ≤88kPa |
Unit size (length ×widthx height mm) | 1030×410×1390 | 860×780×1780 | 1550×780×1780 | 2260×1030×2170 | 2260×1230×2170 | 2260×1230×2170 |
CONNECT SIZE | DN32(hexagon | DN32(hexagon | DN40(hexagon | DN50(flange) | DN65(flange) | DN80(flange) |
Unit weight(kg) | 160 | 215 | 415 | 755 | 1110 | 1250 |
Please contact us for more information about our heat pumps. Our heat pump experts are here to answer all your questions and provide a free quote.