FKH-90II/TGW
LEOMON
| Availability: | |
|---|---|
| Quantity: | |
The unit is specifically designed to produce 150°C saturated steam, meeting the high-temperature requirements of various industrial processes. Advanced heat pump technology delivers stable steam output regardless of ambient temperature variations. The system maintains consistent steam pressure, ensuring reliable performance for critical applications such as sterilization and drying.
Compared with traditional electric resistance boilers, this heat pump saves a substantial portion of energy costs. It captures free heat from ambient air and upgrades it to high-temperature steam, delivering much more thermal energy than the electricity it consumes. When replacing gas or oil-fired boilers, the savings are often even greater.
Equipped with a smart controller, the unit offers automatic operation, scheduled start/stop, and remote monitoring capabilities. Operators can adjust steam parameters from a control room or via mobile devices. The system automatically modulates output based on real-time demand, avoiding energy waste during low-load periods. Alarm notifications and fault diagnostics help reduce downtime and simplify maintenance.
The unit operates with no combustion, no open flame, and zero emissions. There is no risk of gas leakage, explosion, or carbon monoxide poisoning. It produces clean steam without boiler chemicals or combustion residues, making it ideal for industries with strict safety and hygiene requirements. The use of environmentally friendly refrigerants further reduces the impact on the ozone layer and greenhouse effect.
| Stacked air source high-temperature steam heat pump (150 ℃ steam) | ||||||
| Model | FKH-18II/TGW | FKH-45II/TGW | FKH-65II/TGW | FKH-90II/TGW | FKH-130II/TGW | FKH-250II/TGW |
| Generate steam quantity | 30kg | 80kg | 100kg | 160kg | 200kg | 360kg |
| Power Specifications | 380V 3N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz |
| A1 heating capacity (20 ℃) | 20KW | 45KW | 65KW | 90KW | 130KW | 250KW |
| A1 Heating consumption power | 12KW | 28KW | 40.5KW | 56KW | 81KW | 165KW |
| Maximum operating current | 30A | 70A | 120A | 150A | 200A | 400A |
| Noise | ≤72dB(A) | ≤72dB(A) | ≤75dB(A) | ≤80dB(A) | ≤80dB(A) | ≤86dB(A) |
| Unit size (length x width x height mm) | 1600×780×2000 | 2100×780×2000 | 3260×1030×2400 | 3260×1230×2400 | 3260×1230×2400 | 4000×2260×2600 |
| Steam connection size | DN32 | DN32 | DN40 | DN40 | DN40 | DN50 |
| Size of water replenishment connection pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 |
| Unit weight (kg) | 240 | 580 | 1180 | 1430 | 2100 | 5000 |
| The above performance parameters are formulated according to the requirements: | ||||||
| Operating conditions: ambient temperature of 20 ℃, steam temperature of 150 ℃; The minimum operating ambient temperature for this device is 15 ℃. | ||||||
Used for steam cooking, sterilization, drying, and blanching of meat, seafood, vegetables, and grains. The clean steam ensures food safety without contamination from combustion byproducts. Suitable for bakeries, canneries, sauce production, and ready-meal factories. The precise temperature control improves product quality and consistency.
Provides high-temperature steam for reactor heating, distillation columns, reboilers, and steam tracing. Replaces fuel-fired boilers, reducing fuel costs and carbon emissions. Suitable for fine chemical plants, petrochemical facilities, and specialty material production.
Supplies stable 150°C steam for dyeing, heat-setting, drying, and finishing processes. Improves color consistency and fabric quality by maintaining steady steam pressure. Suitable for dye houses, printing mills, and finishing plants. The clean steam prevents staining or contamination of sensitive fabrics.
rovides clean, pure steam for sterilization-in-place, fermenter heating, and equipment sterilization. Suitable for API manufacturing, sterile injectables, and vaccine production. All steam-contacting parts are stainless steel, ensuring steam purity.
>> Product Operate Guide
Upon taking delivery of the goods, the purchaser will furnish an instructional video.
A: Not high. The unit adopts a modular design, which makes installation and maintenance easy. The industrial-grade compressor and components are built for long-term continuous operation. Regular maintenance mainly involves checking filters, electrical connections, and performing periodic inspections. The robust stainless steel construction reduces corrosion and extends service life. Most users find maintenance costs far lower than those of traditional boilers.
A: If there are too many impurities or corrosive substances, it may cause blockage or corrosion of the heat exchanger, affecting the heating efficiency and service life of the heat pump.
Regularly check water quality and install water treatment equipment if necessary.
A: There are no negative impacts. The air source high-temperature heat pump does not have a combustion process during operation, and does not produce pollutants such as exhaust gas and waste residue, which is harmless to the environment. At the same time, using environmentally friendly refrigerants can reduce the damage to the ozone layer and the impact of greenhouse effect.